• Pantelimon - Romania

FIBER CEMENT WALL MONOPANEL WITH POLYURETHANE FOAM

  • Composition: Fiber cement and polyurethane foam
  • Thickness: 50 – 200 mm (includes fiber cement plat)
  • Fiber cement – thickness 10 mm, fire reaction class A2-s1, d0, thermal conductivity index 0.200 W / mK, sound absorption 30 dB
  • Standard dimensions: 1250 mm x 2700 mm

DRYWALL WALL MONOPANEL WITH POLYURETHANE FOAM

  • Composition:drywall and polyurethane foaam
  • Thickness: 60 – 200 mm (includes drywall plates)
  • Drywall – 10 mm thick, fire reaction class A2-s1, d0, thermal conductivity 0.250 W / mK
  • Standard dimensions: 1200 mm x 2600 mm

DRYWALL WALL PANEL

  • Composition: drywall inside and outside, insulating core of polyurethane foam
  • Thickness: 50 – 200 mm (includes drywall plates)
  • Drywall – 10 mm thick, fire reaction class A2-s1, d0, thermal conductivity 0.250 W / mK
  • Standard dimensions: 1200 mm x 2600 mm

WALL MONOPANEL WITH DRYWALL AND POLYSTIRENE

  • Composition: drywall and expanded fireproof polystirene (EPS)
  • Thickness: 40 – 200 mm (includes drywall plates)
  • Drywall – 10 mm thick, fire reaction class A2-s1, d0, thermal conductivity 0.250 W / mK
  • Standard dimensions: 1200 mm x 2600 mm

WALL PANEL DIALTECH® I WITH DRYWALL, 2 LAYERS OF ROCK WOOL AND POLYURETHANE FOAM

  • Composition: drywall / rock wool / insulating core of polyurethane foam / rock wool / drywall
  • Thickness: 100 – 200 mm (includes drywall plates)
  • Drywall – 10 mm thick, fire reaction class A2-s1, d0, thermal conductivity 0.250 W / mK
  • Rock wool – density 160 kg / m3, fire reaction class A1 according to SR EN 13501-1, thermal conductivity 0.04 W / mK
  • Standard dimensions: 1200 mm x 2600 mm
  • Specificity – special properties in terms of thermal insulation and fire resistance.

WALL PANEL DIALTECH® I WITH DRYWALL, ROCK WOOL AND POLYURETHANE FOAM

  • Composition: drywall / polyurethane foam / rock wool / drywall
  • Rock wool – density 160 kg / m3, fire reaction class A1 according to SR EN 13501-1, thermal conductivity 0.04 W / mK
  • Thickness: 80 – 200 mm (includes drywall plates)
  • Drywall – 10 mm thick, fire reaction class A2-s1, d0, thermal conductivity 0.250 W / mK
  • Standard dimensions: 1200 mm x 2600 mm
  • Specificity – special properties in terms of thermal insulation and fire resistance.

FIBER CEMENT WALL PANEL

  • Composition: drywall inside and outside, insulating core of polyurethane foam
  • Thickness: 50 – 200 mm (includes drywall plates)
  • Drywall – 10 mm thick, fire reaction class A2-s1, d0, thermal conductivity 0.250 W / mK
  • Standard dimensions: 1200 mm x 2600 mm

DIALUST 2000 IMPEX S.R.L.

Str. Gara Pasarea 10 Pantelimon jud.Ilfov